PERMEABILITY
Test # ASTM D1551 DIN 18-035 Part 6—Water Permeability of Synthetic Turf Systems and Permeable Bases
|
Sample Identification |
Results |
|
AZ 90, PHX, Tri-Tex |
455.7 inches/hour |
|
|
13.6 sec/6” zone |
|
|
148.53 gal/min/yd² |
The test procedure is used to determine the flow rate of rainfall through a material. A volume of water is poured through the surface and timed. Calculations are then made on the inches of water that would pass through the substrate per hour. The samples were tested as received.
FLAMMABILITY TEST
Test# ASTM E648-2003—Radiant Panel Flammability Test
|
Sample Identification |
Time to Flame Out |
Distance |
Critical Radiant Flux |
|
Specimen #1 |
17.39 min |
16.5 cm |
0.92 W/cm² |
|
Specimen #2 |
16.45 min |
19.5 cm |
0.87 W/cm² |
|
Specimen #3 |
18.31 min |
15.5 cm |
0.94 W/cm² |
|
Average Radiant Flux |
Standard Deviation |
Coefficient of Variation |
|
0.91 |
0.03 |
3.6% |
Specimens of the sample were tested for critical radiant flux in accordance with ASTM testing procedures. The values reported are the average of three specimens.
The samples tested meet or exceed the requirements for NFPA Class 1 as specified by Life Safety Code 101 and IBC 804.2 classification.
|
U.S. Turf Company not responsible for typing errors. | |